Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. bras. cir. cardiovasc ; 36(3): 372-378, May-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1288249

ABSTRACT

Abstract Introduction: In this study, we aimed to investigate the impact of transcatheter aortic valve implantation (TAVI) on serum apelin levels in patients with severe symptomatic aortic valve stenosis (AS). Methods: Forty-six consecutive patients (76.9±7.4 years, n=27 women) who underwent TAVI and 45 age- and sex-matched control subjects were included in the study. Echocardiographic parameters, serum apelin, pro-brain natriuretic peptide (Pro-BNP), and troponin I levels were compared between the groups. In addition, the preprocedural and first-month follow-up echocardiographic parameters and serum apelin values of TAVI patients were compared. Results: Serum median troponin I and Pro-BNP levels were significantly higher and serum apelin levels were significantly lower in TAVI patients before TAVI procedure than in the control subjects (P<0.001, for all). Median troponin I and Pro-BNP levels were significantly decreased and apelin levels were significantly increased after TAVI procedure compared to the peri-procedural levels. There was a significant and moderate negative correlation between Pro-BNP and apelin levels measured before and after TAVI procedure. A statistically significant and strong negative correlation was found between aortic valve area and Pro-BNP level before TAVI procedure, while a statistically significant but weak positive correlation was found between valve area and apelin level. Conclusion: In our study, apelin levels were significantly lower and Pro-BNP levels were higher in AS patients compared with the control group. Moreover, after TAVI procedure, a significant increase in apelin levels and a significant decrease in Pro-BNP levels were observed. There was also a negative and moderate correlation between apelin and Pro-BNP levels.


Subject(s)
Humans , Female , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Echocardiography , Treatment Outcome , Constriction, Pathologic , Apelin
2.
Rev. bras. cir. cardiovasc ; 35(4): 504-511, July-Aug. 2020. tab, graf
Article in English | LILACS, SES-SP | ID: biblio-1137287

ABSTRACT

Abstract Introduction: Recently, the clinical significance of mild paravalvular aortic regurgitation (PAR) has been evaluated and suggested that it can be predictor of clinical outcomes. In our study, we aimed to investigate the interaction of aortic pulse wave velocity (PWV) and mild PAR and their effects on the functional status of patients after transcatheter aortic valve implantation (TAVI). Methods: A total of 109 consecutive patients with symptomatic severe aortic stenosis were enrolled prospectively. After TAVI procedure, they were divided in to three groups according to PAR and PWV measurements. Patients without PAR were defined as the NonePAR group (n=60), patients with mild PAR and normal PWV were defined as the MildPAR-nPWV group (n=23), and patients with mild PAR and high PWV were defined as the MildPAR-hPWV group (n=26). Results: Compared with other groups, the MildPAR-hPWV group was older (P<0.001), hypertensive (P=0.015), and had a higher pulse pressure (P=0.018). In addition to PWV, this group had lower aortic regurgitation index (ARI) (P=0.010) and higher rate of New York Heart Association (NYHA) class II (at least) patients (P<0.001) in 30-day follow-up period. On multivariate regression analysis, the MildPARhPWV group (odds ratio=1.364, 95% confidence interval 1.221-1.843; P=0.011) as well as N-terminal-pro-brain natriuretic peptide levels and ARI were independently related with 30-day functional NYHA classification. However, NonePAR or MildPAR-nPWV group was not an independent predictor of early functional status. Conclusion: It was concluded that high PWV may adversely affect early functional status in patients with mild PAR in contrast to normal values following TAVI.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Severity of Illness Index , Angiotensin-Converting Enzyme Inhibitors , Treatment Outcome , Angiotensin Receptor Antagonists , Pulse Wave Analysis
3.
Braz. j. otorhinolaryngol. (Impr.) ; 83(1): 45-49, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-839404

ABSTRACT

Abstract Introduction Epistaxis and hypertension are frequent conditions in the adult population. Masked hypertension is defined as a clinical condition in which a patient's office blood pressure level is <140/90 mmHg, but the ambulatory or home blood pressure readings are in the hypertensive range. Many studies have proved that hypertension is one of the most important causes of epistaxis. The prevalence of this condition in patients with epistaxis is not well defined. Objective This study aimed to evaluate the prevalence of masked hypertension using the results of office blood pressure measurement compared with the results of ambulatory blood pressure monitoring. Methods Sixty patients with epistaxis and 60 control subjects were enrolled in the study. All patients with epistaxis and controls without history of hypertension underwent physical examination, including office blood pressure measurement, ambulatory or home blood pressure, and measurement of anthropometric parameters. Results Mean age was similar between the epistaxis group and the controls – 21–68 years (mean 42.9) for the epistaxis group and 18–71 years (mean 42.2) for the control group. A total of 20 patients (33.3%) in the epistaxis group and 7 patients (11.7%) in the control group (p = 0.004) had masked hypertension. Night-time systolic blood pressure was significantly higher in patients with epistaxis than in the control group (p < 0.005). However, no significant difference was found in daytime systolic blood pressure between the control group and the patients with epistaxis (p = 0.517). Conclusion This study demonstrates increased masked hypertension prevalence in patients with epistaxis. We suggest that all patients with epistaxis should undergo ambulatory or home blood pressure to detect masked hypertension, which could be a possible cause of epistaxis.


Resumo Introdução Epistaxe e hipertensão são condições frequentes na população adulta. Hipertensão mascarada é definida como uma condição clínica em que o nível da pressão arterial do paciente no consultório é < 140/90 mm Hg, mas as leituras da pressão arterial ambulatorial ou em casa se encontram na faixa hipertensiva. Muitos estudos demonstraram que a hipertensão é uma das causas mais importantes de epistaxe. Ainda não está devidamente definida a prevalência dessa condição em pacientes com epistaxe. Objetivo Avaliar a prevalência de HM com o uso dos resultados de mensurações da pressão arterial no consultório, em comparação com os resultados da MAPA. Método Foram recrutados 60 pacientes com epistaxe e 60 indivíduos para controle. Todos os pacientes com epistaxe e os controles sem histórico de hipertensão passaram por exame físico, inclusive determinação da pressão arterial no consultório, MAPA e mensuração dos parâmetros antropométricos. Resultados A média de idade foi similar entre o grupo com epistaxe e os controles: de 21 a 68 (média 42,9) anos para o grupo com epistaxe e de 18 a 71 (média 42,2) anos para o grupo controle. No total, 20 pacientes (33,3%) no grupo com epistaxe e sete (11,7%) no grupo controle (p = 0,004) apresentaram hipertensão mascarada. A pressão arterial sistólica noturna foi significantemente mais alta em pacientes com epistaxe, em comparação com o grupo controle (p < 0,005). No entanto, não foi observada diferença significante na pressão arterial sistólica obtida durante o dia entre o grupo controle e os pacientes com epistaxe (p = 0,517). Conclusão O presente estudo demonstra maior prevalência de hipertensão mascarada em pacientes com epistaxe. Sugerimos que todos os pacientes com epistaxe devam ser submetidos à monitoração da pressão arterial caseira ou em consultório com o objetivo de detectar hipertensão mascarada, que pode ser uma causa possível de epistaxe.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Young Adult , Epistaxis/etiology , Masked Hypertension/complications , Case-Control Studies , Prevalence , Prospective Studies , Blood Pressure Monitoring, Ambulatory , Masked Hypertension/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL